首页> 外文会议>MISM2008;Moscow international symposium on magnetism; 20080620-25;20080620-25; Moscow(RU);Moscow(RU) >AN EMI IMMUNITY STUDY OF TMR HEADS IN QUASI-STATIC TESTER DUE TO THE DIRECTION OF SWEEPING FREQUENCY
【24h】

AN EMI IMMUNITY STUDY OF TMR HEADS IN QUASI-STATIC TESTER DUE TO THE DIRECTION OF SWEEPING FREQUENCY

机译:定向扫描频率的准静态测试仪中TMR头的EMI抗扰性研究

获取原文
获取原文并翻译 | 示例

摘要

This report aims to investigate a comparative effect of Electromagnetic Interference (EMI) on recording heads due to sweeping directions of low-to-high and high-to-low frequencies. Four selected Quasi-Static Tester (QST) parameters; MR resistance, MR amplitude asymmetry, Barkhausen noise and Hysteresis, are used for monitoring the effect of EMI on Head Gimbal Assembly (HGA). It is undoubtedly found that the Asymmetry and Hysteresis parameters provide insufficient indication of EMI effect for both sweeping frequency directions. On the other hand, it is discovered that the sweeping direction of the low-to-high frequency is more effective to two test parameters; MR resistance and Barkhausen noise, than the other direction. The dramatic energy accumulation is possibly explained this phenomenon but this energy level is not high enough to cause the Hysteresis change.
机译:本报告旨在研究由于低频到高频和高频到低频的扫描方向而在记录头上产生电磁干扰(EMI)的比较效果。四个选定的准静态测试器(QST)参数; MR电阻,MR振幅不对称性,巴克豪森噪声和磁滞现象用于监视EMI对磁头万向架组件(HGA)的影响。毫无疑问,对于两个扫描频率方向,“不对称”和“滞后”参数都无法充分表明EMI效应。另一方面,发现从低频到高频的扫描方向对于两个测试参数更有效。 MR电阻和Barkhausen噪声比另一个方向大。巨大的能量积累可能可以解释这种现象,但是这种能量水平不够高,不会引起磁滞变化。