首页> 外文会议>Metropolis amp; beyond >March 2003 Denver Blizzard - A RetrospectivePART II: Building Code Requirements for Repairs
【24h】

March 2003 Denver Blizzard - A RetrospectivePART II: Building Code Requirements for Repairs

机译:2003年3月,丹佛暴雪(Denver Blizzard)-回顾PART II:维修的建筑规范要求

获取原文
获取原文并翻译 | 示例

摘要

This paper reviews past and current building code provisions for repairing damage tornexisting buildings. Shortfalls, ambiguities and contradictions in the code discoveredrnduring the course of designing repairs to buildings damaged during the March 2003rnblizzard in Denver, Colorado are discussed. The paper discusses the significantrnchallenges involved in providing responsible engineering services for the repair ofrndamaged structures considering current code and jurisdictional requirements andrnattempts to clarify the requirements with authoritative interpretations from codernofficials. Recommendations for improving repair provisions in the code arernpresented.
机译:本文回顾了过去和当前的建筑法规规定,以修复已损坏的建筑物。讨论了在对科罗拉多州丹佛市2003年3月暴风雪造成的建筑物进行维修设计时发现的规范中的不足,歧义和矛盾之处。本文讨论了在考虑现行法规和管辖要求的情况下为受损结构的维修提供负责任的工程​​服务所涉及的重大挑战,并试图通过规范官员的权威解释来澄清要求。提出了改进规范中的维修规定的建议。

著录项

  • 来源
    《Metropolis amp; beyond》|2005年|1-12|共12页
  • 会议地点 New York NY(US)
  • 作者

    Bruno Lutz;

  • 作者单位

    Martin/Martin Inc., 12499 West Colfax Avenue, Lakewood, Coloradornphone 303-431-6100 blutz@martinmartin.com;