Faults in electrical machines or their drives lead to degraded performance and, in some cases, unsafe operating conditions. MOSFET devices in an inverter-drive allow for higher switching frequencies. However, both power MOSFETs and Silicon Carbide MOSFETs experience degradation in the insulating gate oxide layer from excess voltage or temperature. Indicators of gate oxide degradation are measurable, but many require access to the leads of the device and additional voltage or current sensors. For an inverter-drive application, current sensors are commonly employed for controlling the machine. Detecting gate oxide degradation in the measured phase currents is noninvasive and can be performed online. In this work, degradation of gate oxide is performed in power MOSFETs and the corresponding changes in current transient waveforms are quantified.
机译:电机或其驱动器中的故障导致性能降低,并且在某些情况下,不安全的操作条件。逆变器驱动器中的MOSFET器件允许更高的开关频率。然而,功率MOSFET和碳化硅MOSFET在绝缘栅极氧化物层中的劣化免于过量的电压或温度。栅极氧化物劣化的指示是可测量的,但许多需要访问装置的引线和附加电压或电流传感器。对于逆变器驱动应用,通常用于控制机器的电流传感器。检测测量的相电流中的栅极氧化物劣化是非侵入性的并且可以在线进行。在这项工作中,在功率MOSFET中执行栅极氧化物的劣化,并且量化电流瞬态波形的相应变化。