摘要

The purpose of this research was to study on the design and construction of infusion pump calibrator. This research has adopted the principle of physics, electronics and microcontroller. The designed and constructed the infusion pump calibrator was composed of three main parts: l)the control part consisting of micro switches for selected the operating mode, 2) signals detection part composing of load cells, pressure sensor for measuring flow rate and occlusion alarm respectively and3) the processing and display part comprising of microcontroller AVR ATmega1280 with С Language program and LCD sequentially. The results of functional testing were compared with standard infusion devices analyzer Metron Lagu showed that the average percentage error of flow rate measuring and occlusion pressure tests were 0.45 percent and 0.21 percent successively.
机译:本研究的目的是研究输液泵校准器的设计和施工。 该研究采用了物理,电子和微控制器的原理。 设计和构造的输液泵校准器由三个主要部分组成:l)控制部件由微开关组成,用于选择操作模式,2)信号检测部件组成的负载电池,分别测量流量和遮挡报警的压力传感器 [3)处理和显示部分,包括微控制器AVR ATMEGA1280,其顺序使用С语言程序和LCD。 与标准输液装置进行比较功能测试的结果分析仪元素LAGU,表明流速测量和闭塞压力测试的平均百分比误差连续0.45%和0.21%。