This paper proposes a systematic approach to calculate the customer interruption cost due to the effect of hidden failure in a power system. The distribution of electrical energy from the generation to the consumer might experience interruption due to some specific reasons. One of the reasons that could give catastrophic impact to the system is due to cascading collapse that might happen in the system. In this paper, the reliability cost from the customer's perspective being conducted in order to analyse the interruption cost based on cascading collapse. The analysis has been carried out from some sectors of the building that use the source of energy. Analysis has been made by using IEEE Reliability Test System 1979 (IEEE RTS-79) in order to verify the proposed technique is accurate. The total loading condition of the system have been calculated for this analysis in order to investigate the reliability cost towards the customers based on the interruption cost. The average probability of system cascading collapse and interruption cost of the failure shows a great impact to the consumer if the system is collapsed.
机译:本文提出了一种系统的方法来计算由于电力系统中的隐藏失败的影响而计算客户中断成本。由于某些具体原因,从生成到消费者的电能分布可能会遇到中断。可能对系统产生灾难性影响的原因之一是由于系统中可能发生的级联崩溃。本文从客户的角度进行了可靠性成本,以分析基于级联崩溃的中断成本。该分析已从建筑物的某些部门进行,这些部门使用能量来源。通过使用IEEE可靠性测试系统1979(IEEE RTS-79)进行了分析,以验证所提出的技术是准确的。已经计算了该分析的系统总装载条件,以根据中断成本调查客户的可靠性成本。如果系统崩溃,则失效的系统级联崩溃和中断成本的平均概率显示出对消费者的很大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号