The issue of increasing energy consumed in buildings and the need for thermal insulation regulations has become a major concern in Palestine with increasingly alarming warnings of climate change and the depletion of fossil fuels. In this study, the overall heat transfer coefficient U-value in the Palestinian energy-efficient building code was reviewed for walls, floors, roofs, doors, and windows. U-value expresses the amount of heat transfer from the building to the external outside air. U-value was investigated concerning the average value for the U-value (Average U-value), heating degree days, and energy consumption due to the heating load. The investigation in this study suggested a new average U-value of 0.85 W/m2.K was suggested which can result in approximately 44% energy saving and make the energy consumption in the Palestinian residential buildings comparable to the values of the International Energy Consumption Codes.
机译:在建筑物中消耗的能量和保温保温规定的需求增加的问题已成为巴勒斯坦的主要问题,随着气候变化的越来越令人震惊的警告和化石燃料的枯竭。在这项研究中,墙壁,地板,屋顶,门和窗户审查了巴勒斯坦节能建筑规范中的总传热系数U值。 U值表达从建筑物到外部空气的传热量。研究了U值的U值(平均U值),加热度天和由于加热负荷而产生的平均值。该研究的调查表明,新的平均U值为0.85 w / m 2 建议,这可能导致大约44%的节能,并使巴勒斯坦住宅建筑物能耗相当,可与国际能源消费代码的价值观相当。

著录项