首页> 外文会议>International Conference on Advances in Engineering and Technology Research >Mechatronics device for tremor sensing and cancellation for accuracy enhancement in microsurgeries
【24h】

Mechatronics device for tremor sensing and cancellation for accuracy enhancement in microsurgeries

机译:机电一体化装置,用于震颤感应和消除微型磨术中精度增强

获取原文

摘要

An involuntary muscle motion is known as tremors. During microsurgeries which includes the operation of delicate organs like eye, ear etc. tremors deteriorate surgeon micromanipulation ability. This further may causes severe damage to the surrounding tissues under operation. This paper proposes a hand held mechatronics device for real time sensing and active cancellation of tremor motions using piezoelectric bending actuators. Device incorporates inertial sensor to sense surgeons hand motion, adaptive filter with zero phase delay to differentiate between voluntary & tremor motion Three piezoelectric bending actuator assemblies provides linear actuation along Z axis in order to move tool tip in equal and opposite direction of tremor motion which maintains tool tip at desired position with active tremor cancellation.
机译:非自愿的肌肉运动被称为震颤。在显微磨术期间,包括像眼睛,耳朵等精致器官的操作。震颤越差地改变外科医生的微操纵能力。这进一步可能导致术后对周围组织的严重损害。本文提出了一种手持式机电一体化装置,用于使用压电弯曲致动器的实时感测和积极消除震颤运动的主动取消。器件包含惯性传感器来感测外科医生手动运动,具有零相位延迟的自适应滤波器,以区分自愿和颤动运动三个压电弯曲致动器组件沿Z轴提供线性致动,以便在维护的震颤运动中等于且相反的方向移动刀尖刀具提示处于所需位置,具有主动震颤消除。

著录项