首页> 外文会议>International Conference on Digital Image Computing Techniques and Applications >An Automatic Image Based Single Dilution Method for End Point Titre Quantitation of Antinuclear Antibodies Tests Using HEp-2 Cells
【24h】

An Automatic Image Based Single Dilution Method for End Point Titre Quantitation of Antinuclear Antibodies Tests Using HEp-2 Cells

机译:一种基于自动图像的单点滴度法,用于使用HEP-2细胞进行抗核抗体试验的终点滴定定量

获取原文

摘要

Indirect Immunofluorescence (IIF) on Human epithelial (HEp-2) cells test has been the golden standard for identifying the presence of Anti-Nuclear Antibodies (ANA) due to its high sensitivity and the large range of antigens that can be detected. Furthermore, IIF ANA test allows the positive sample strength (sample end point titre) to be reported. Despite its advantages, the IIF ANA test needs to be performed manually, and therefore it is perceived as an expensive and laborious process. This also applies to determining the strength of positive samples (end point titre) which traditionally is done by serially diluting the specimen. In this paper, we present an image-based method which is able to automatically determine the end point titre of positive samples based only on a single screening dilution. This can be done by simulating the manual titration process using a mathematical model of the exposure-density curve. Technically, a new Image Titration Endpoint (ITE) unit based on the model is introduced. Each specimen image is then measured in terms of this unit. Finally, the end point titre for the specimen is determined through a standard curve which specifies the end point titre given an ITE unit. This process is fully automated which would give an advantage over the current digital titration methods. The overall endpoint titre agreement between the proposed approach and the manual serial dilution method in the evaluation of 134 positive samples was 100%. This high agreement demonstrates that the proposed approach is suitable for routine ANA IIF testing in the clinical settings.
机译:在人上皮(HEP-2)细胞上的间接免疫荧光(IIF)是由于其高灵敏度和可以检测到的大范围的抗原而识别抗核抗体(ANA)的存在的金标准。此外,IIF ANA测试允许报告正样的样品强度(样品终点滴度)。尽管有其优势,但需要手动执行IIF ANA测试,因此它被认为是一种昂贵和艰苦的过程。这也适用于确定传统上通过连续稀释样品来完成的正样品(终点滴度)的强度。在本文中,我们介绍了一种基于图像的方法,其能够仅基于单次筛选稀释来自动确定正样的末端滴度。这可以通过使用曝光密度曲线的数学模型模拟手动滴定过程来完成。从技术上讲,引入了基于模型的新图像滴定端点(ITE)单元。然后根据本机测量每个样品图像。最后,通过标准曲线确定标本的终点标题,该标准曲线指定给出ITE单元的终点滴度。该过程是完全自动化的,这将提供优于当前的数字滴定方法。在评价134阳样品中,提出的方法和手动连续稀释方法之间的总体终点滴度协同为100%。这项高协议表明,所提出的方法适用于临床环境中的常规ANA IIF测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号