Design and Analysis of Resonant Inverter-Based Induction Heating Equipment

机译:基于谐振逆变器的感应加热设备的设计与分析

获取原文

摘要

We have seen that harmonics play a big drawback role in any electrical circuit. One of the major effects of harmonics in power system is the increase in distortion of input current in the system. The dominant harmonic decreases the reliability of the entire system and its elimination becomes necessary to make the IHE a worthy technology. A detailed analysis of the IHE technology with and without the filter circuit is discussed to highlight the amount of distortions present in the current waveform. The hysteresis controller technique is implemented for its easy control and faster response. In this paper, the calculation of THD with and without filter circuit is discussed which shows drastic change of distortion value from 28.76% to 12.47% in the input waveform and hence the use of shunt active power filter (SAPF) is justified. Only then the induction heating technique can replace the existing conventional heating systems in the industry and make this greener approach a successful one.
机译:我们已经看到谐波在任何电路中发挥着大的缺点作用。 谐波在电力系统中的主要影响之一是系统中输入电流变形的增加。 主导谐波降低了整个系统的可靠性,并且必须使IHE成为一个有价值的技术所必需的。 讨论了具有和不具有滤波器电路的IHE技术的详细分析,以突出显示当前波形中存在的扭曲量。 磁滞控制器技术用于其易于控制和更快的响应。 在本文中,讨论了具有和不带滤波器电路的THD的计算,其显示在输入波形中的失真值的急剧变化为28.76%至12.47%,因此使用分流有源电力滤波器(SAPF)是合理的。 只有那么感应加热技术只能取代行业中现有的传统加热系统,并使这种更环保的方法成功。