Energy use in water supply systems represents a significant portion of the global energy consumption.The electricity consumption due to the water pumping represents the highest proportion of the energy costs in these systems.The main objective of this paper is to observe the different power quality issues generated at the point of common coupling of a grid tied PV supplying power to the pumping motor for different preset pressures and taking readings at different loading conditions.The obtained results have been analyzed and valid conclusion is made on various power quality issue parameters like harmonics,voltage sag or swells levels etc.At the end suitable mitigation techniques to solve the PQ issues in a grid tied PV has been proposed.
机译:供水系统中的能源使用代表全球能源消耗的重要部分。由于水泵引起的电力消耗代表了这些系统中的能源成本的最高比例。本文的主要目的是观察不同的电能质量问题 在泵送电动机的网格连接的公共耦合点以不同的预设压力供电并在不同的负载条件下进行读数。已经分析了所得的结果,并且在各种电力质量问题参数上进行了有效的结论,如谐波, 已经提出了电压凹槽或膨胀级别。已经提出了解决网格绑定PV中解决PQ问题的最终适当的缓解技术。