首页> 外文会议>International Conference on Fluidized Bed Technology >MEASUREMENT OF SOLIDS VELOCITY AND CONCENTRATION IN A LARGE COLD CFB MODEL
【24h】

MEASUREMENT OF SOLIDS VELOCITY AND CONCENTRATION IN A LARGE COLD CFB MODEL

机译:大型冷CFB模型中固体速度和浓度的测量

获取原文

摘要

This work applies optical probe and particle image velocimetry (PIV) measurements for determining the local characteristics of the solids flow in a CFB riser and discusses benefits and limitations of the two methods.Measurements were carried out in an 8.5 m tall CFB riser with a cross-section of 0.7 m x 0.12 m.The optical probe was used to measure both solids volume fraction and velocity whereas the PIV was limited to solids velocity measurements.In addition, the vertical pressure profile and solids circulation rate were measured by means of pressure transducers.The work demonstrates the challenge of applying detailed solids flow measurements in CFB reactors.Both methods applied are associated with limitations and inaccuracies and it is concluded that a combination of both local measurement methods and the global pressure measurements will improve the interpretation of the solids flow field in CFB risers.
机译:该工作适用于光学探针和粒子图像速度(PIV)测量来确定CFB提升板中固体流动的局部特性,并讨论两种方法的益处和局限性。在8.5米的高CFB立管中进行了若干 - 选择0.7m×0.12米。光学探针用于测量固体体积分数和速度,而PIV限于固体速度测量。此外,通过压力传感器测量垂直压力曲线和固体循环速率。该工作证明了在CFB反应器中应用详细的固体流量测量的挑战。所施加的方法与限制和不准确相关,并且得出结合,局部测量方法和全球压力测量的组合将改善固体流场的解释在CFB立管中。