摘要

A movable test system for thermal performance of domestic solar water heating system is proposed to solve the problem that fixed test system has low utilization efficiency of climatic resources. The test system consists of a bus body, closed pipeline system, measurement and control system for temperature and flow, mobile electric cabinet, etc.. The temperature and flow in thermal performance test can be controlled respectively in -0.2°C~+0.2°C. The mathematic model of daily useful energy of the test system has been established. By analyzing measurement uncertainty components of daily useful energy, its relative expanded uncertainty is 3.2%. The movable system can make full use of climate resources of different geographical areas and improve test efficiency.
机译:提出了一种用于国内太阳能热水系统的热性能的可移动测试系统,解决了固定试验系统具有低利用效率的气候资源的问题。 测试系统由总线体,封闭管道系统,用于温度和流量,移动电动柜等的测量和控制系统组成。热性能测试中的温度和流量分别在-0.2°C〜+ 0.2°中进行控制 C。 已经建立了测试系统的日常有用能量的数学模型。 通过分析日常有用能量的测量不确定性组分,其相对扩张的不确定性是3.2%。 可移动系统可以充分利用不同地理区域的气候资源,提高测试效率。