首页> 外文会议>International Conference on Civil Engineering, Architecture and Building Materials >Research for Start-up Experiment about IC Reactor to Treat Straw-washing Wastewater in Straw based Pulping and Papermaking
【24h】

Research for Start-up Experiment about IC Reactor to Treat Straw-washing Wastewater in Straw based Pulping and Papermaking

机译:IC反应器的启动试验研究秸秆水稻秸秆及造纸治疗秸秆洗涤废水

获取原文

摘要

In this paper, an IC reactor whose effective volume was 6m3 was used in the experiment to determine the best condition when decontaminating the straw-washing water produced in the straw-based pulping and papermaking industry. The best condition of IC reactor to treat straw-washing wastewater through experiment was: the pH should be controlled in the neutral range, not less than 6.6; the temperature should be maintained at about 31°C, not more than 35°C; the fluctuation range of volume loading should better not be over 15%; To meet the alkalinity of the reactor over 1000 mg/L, the dosage of sodium bicarbonate was 12 kg/d. In the processing of reactor treating straw-washing wastewater, COD removal rate was lower, and effluent VFA stayed at a high level continuously. So the hydrolysis-acidification process was more appropriate than anaerobic treatment when decontaminating the straw-washing water.
机译:在本文中,在实验中使用了其有效体积为6m3的IC反应器,以确定在秸秆基制浆行业中产生的吸管水分脱屑时确定最佳条件。 通过实验处理秸秆洗涤废水的IC反应器的最佳条件是:pH应控制中性范围,不小于6.6; 温度应保持在约31°C,不超过35°C; 体积负荷波动范围应更好地不超过15%; 为了满足1000mg / L以上反应器的碱度,碳酸氢钠的剂量为12kg / d。 在处理秸秆洗涤废水的反应器的加工中,COD去除率较低,流出VFA连续停留在高水平。 因此,当剥离吸管水时,水解酸化过程比厌氧处理更合适。