首页> 外文会议>International Conference on Recent Trends in Materials and Mechanical Engineering >Effects of Exterior Window on Temperature Distribution and Thermal Comfort of Commercial Buildings with Radiant Floor Heating System
【24h】

Effects of Exterior Window on Temperature Distribution and Thermal Comfort of Commercial Buildings with Radiant Floor Heating System

机译:外窗对带辐射地板加热系统的商业建筑温度分布及热舒适的影响

获取原文

摘要

The purpose of this study is to investigate the effect of boundary conditions on the temperature distribution and thermal comfort of a radiant floor heating system and their practical application to commercial buildings. Indoor thermal environment, along with human response, was studied by means of CFD. The three-dimensional temperature distribution was numerically simulated with the zero-equation turbulent model. And two typical operating models, which there is and there is no windows in the room were analyzed in detail. The results show that the radiant floor heating system can meet the demand of comfortable degree, and that the temperature field is enormously influenced by boundary conditions. It is necessary to install curtains to decrease the radiant heat transfer of the cooling glass surface and other control methods to ensure the room to be a thermal comfortable environment.
机译:本研究的目的是研究边界条件对辐射地板加热系统温度分布和热舒适性的影响及其在商业建筑物的实际应用。通过CFD研究室内热环境以及人类反应。用零方程湍流模型进行数值模拟三维温度分布。还有两个典型的操作模型,还有房间内没有窗户的窗户进行了详细分析。结果表明,辐射地板加热系统可以满足舒适程度的需求,并且温度场极大地受边界条件的影响。有必要安装窗帘以降低冷却玻璃表面和其他控制方法的辐射传热,以确保房间成为热舒适的环境。