Inadvertent cuts to blood vessels and nerves poses a significant risk during percutaneous needle procedures, often leadingto serious injuries and even death. We propose a computer-assisted photoacoustic imaging-based device that is able todetect these vascular structures and robotically guide the surgeons in avoiding them. A fiber-coupled pulsed laser diodecapable of generating photoacoustic signals is attached through a ferrule, where a 2.5 mm diameter ultrasound ringtransducer receives the corresponding photoacoustic waves. The integrated device is secured on an XYZ axis lineartranslational stage configuration, and robotically navigated through vessel-modelling phantoms to reach a targeted regionof interest. A steering feedback algorithm calculates the relative position of the device with respect to each vessel, generatesa 2D map of the navigational plane, and controls the stages to steer the device accordingly towards the target while avoidingthe vessels. We first ran the algorithm in a water phantom to demonstrate feasibility, and then in a milk solution to modelreal tissue scattering. Our proposed device successfully avoids the phantom blood vessels in both cases throughphotoacoustic detection, and the corresponding 2D navigational path and plane through the phantom is mapped andrecorded. Our results demonstrate that a computer-assisted photoacoustic imaging-based device is a viable method ofintraoperatively guiding percutaneous needle procedures. The ability of our proposed guidance device to detect and avoiddamage to blood vessels and nerves can further be used to optimize biopsies and tumor removal procedures in variousparts of the body.
机译:无意中切断血管和神经在经皮针手术期间构成了显着的风险,通常是领先的严重伤害甚至死亡。我们提出了一种能够的计算机辅助光声成像的设备检测这些血管结构并机器人引导外科医生避免它们。纤维耦合脉冲激光二极管能够通过套圈连接光声信号,其中2.5mm直径的超声环换能器接收相应的光声波。集成装置固定在XYZ轴线上翻译阶段配置,并通过船舶建模幻影机器人导航到目标区域出于兴趣。转向反馈算法计算设备相对于每个船只的相对位置,产生导航平面的2D映射,并控制阶段以相应地朝向目标转向设备,同时避免船只。我们首先在水幻影中运行算法,以证明可行性,然后在牛奶解决方案到模型中真正的组织散射。我们所提出的装置通过两种情况避免了幽灵血管光声检测,以及相应的2D导航路径和通过幻像的平面映射和记录。我们的结果表明,基于计算机辅助光声成像的设备是一种可行的方法脑医引导经皮针手术。我们提出的指导设备检测和避免的能力血管和神经的损伤可以进一步用于优化各种活组织检查和肿瘤去除程序身体的一部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号