The influence of wastewater containing benzene from chemical industry by technology combined blow-off with Fenton reagent oxidation was experimentally studied. The present results suggest that the technology combined blow-off with Fenton reagent oxidation can effectively remove benzene pollutant in wastewater. The main factors that influence the removal benzene such as temperature and blowing time and volume, pH and reagent dosage of H202 and Fe2+ are studied and the optimal experimental conditions are as follows: time 20min, temperature 40 square, air-blowing volume 0.4L/min, pH value 5, and H202 and Fe2+ dosage 2mL/L and 200mg/L respectively. Under the above conditions, benzene pollutant can be removed up to 97 percent . Compared to other removal ways of wastewater containing benzene, the technology combined blow-off with Fenton reagent oxidation is more effective and has the advantage of high speed.
机译:实验研究了通过技术组合爆破含有Fenton试剂氧化的废水从化学工业的废水的影响。本结果表明,用芬顿试剂氧化的技术组合吹扫可以有效地除去废水中的苯污染物。研究了影响去除苯如温度和吹风时间和体积,pH和试剂剂量的主要因素,并进行最佳的实验条件如下:时间20分钟,温度40平方,空气吹送量0.4L /分别,pH值5和H202和Fe2 +剂量分别为2ml / L和200mg / L.在上述条件下,苯污染物可高达97%。与含苯的废水的其他去除方式相比,技术组合吹气与Fenton试剂氧化更有效并且具有高速的优点。