摘要

While not necessarily implanted into the body, a variety of tools are used during the course of a surgery that make contact with internal body fluids and tissues. Keeping reusable tools in good condition and corrosion-free is obviously important. Laser etching is one means of placing identifying marks on such tools without introducing additional materials such as inks, dyes, adhesives, etc. However, laser-etched areas can sometimes develop corrosion due to sensitization in the etch area caused by excessive local heating. The results reported here represent an initial effort to identify a potentiodynamic means of inducing corrosion in the laser-etched areas of stainless steel tools if localized sensitization occurred as a result of overheating during the etching procedure. The electrochemical technique should be able to distinguish between “good” and “bad” etches relatively quickly so that it may be used to help refine the laser etch process, and ultimately assist in quality assurance screening for laser etched items sold for use in surgical or other medical environments.
机译:虽然不一定植入体内,但在手术过程中使用各种工具,该工具与内部体液和组织接触。保持可重复使用的工具状况良好和无腐蚀性显然很重要。激光蚀刻是在这种工具上放置识别标记的一种方法,而不引入诸如油墨,染料,粘合剂等的附加材料,因此激光蚀刻区域有时可以在由过量的局部加热引起的蚀刻面积中引起腐蚀。这里报道的结果代表了识别不锈钢工具的激光蚀刻区域中诱导腐蚀的电位动力学手段,如果局部致敏在蚀刻程序期间过热时发生局部敏化。电化学技术应该能够相对迅速地区分“良好”和“良好”蚀刻,以便它可用于帮助改进激光蚀刻工艺,并最终有助于用于销售用于外科或者用于外科的激光蚀刻物品的质量保证筛选其他医疗环境。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号