首页> 外文会议>National Association of Corrosion Engineers Conferences >FIELD TRIAL OF IMPRESSED CURRENT, SACRIFICIAL ANODE, CONSTANT VOLTAGE, AND INTERMITTENT CATHODIC PROTECTION ON A STEEL REINFORCED COASTAL BRIDGE
【24h】

FIELD TRIAL OF IMPRESSED CURRENT, SACRIFICIAL ANODE, CONSTANT VOLTAGE, AND INTERMITTENT CATHODIC PROTECTION ON A STEEL REINFORCED COASTAL BRIDGE

机译:钢筋沿海桥上印象电流,牺牲阳极,恒压和间歇阴极保护的现场试验

获取原文

摘要

Equipment has been designed and installed for a field trial being conducted on a coastal reinforced concrete bridge with a newly installed cathodic protection (CP) system. The purpose of the field trial is to determine the optimum form of intermittent CP for protecting coastal bridges. The forms of CP that were considered for the field trial are: (1) impressed current CP as the control; (2) current-interrupted ICCP; (3) corrosion rate monitoring device controlled ICCP; (4) constant voltage CP; and (5) sacrificial anode CP. Once the test is initiated, the performance of these four forms of CP on a coastal RC bridge and their effectiveness in providing protection to reinforcing steel will be is compared with that achieved by present Oregon Department of Transportation ICCP practices. Details are presented on the set up of the experiment and the logic used to control CP intermittently. The field trial is scheduled to be started early 2007.
机译:设备设计并安装了在沿海钢筋混凝土桥上进行的现场试验,具有新安装的阴极保护(CP)系统。现场试验的目的是确定用于保护沿海桥梁的间歇性CP的最佳形式。用于现场试验的CP的形式是:(1)印象印象的电流CP为控制; (2)当前中断的ICCP; (3)腐蚀速率监测装置控制ICCP; (4)恒压CP; (5)牺牲阳极CP。一旦开始测试,将在沿海RC桥上的这四种形式的CP的性能及其在为加固钢保护提供保护方面的效力将与目前俄勒冈州交通委员会的俄勒冈州交易所国际电联实践所取得的比较。详细介绍了实验的设置和用于控制CP的逻辑间歇性。现场试验计划于2007年初开始。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号