This paper discusses performance of tall steel structures with dual system (comprised of SMRFs and Intermediate RC shear walls) in near-fault ground motions according to acceptance criteria introduced in FEMA356 and ATC40. Achieving this purpose and in comparison with far-fault ground motions and evaluating acceptability of push-over analyses in performance based design method, some nonlinear time history analyses under near-field and far-field records and some nonlinear static analyses are performed. There after acceptance criteria of structures is checked. The results show that despite of appropriate performance of dual system under far- fault excitations, structural performance is not acceptable under near-fault ground motions because of inadmissible story drifts. Deficiency of Iranian code (Standard No. 2800) in exhibition of critical load combination for column's seismic design and inadequacy of push-over analysis in demonstrating tall buildings performance are other results of this study.
机译:本文讨论了在FEMA356和ATC40中引入的验收标准,在近断层地运动中使用双系统(SMRF和中间RC剪切墙组成的高钢结构(包括SMRF和中间RC剪切墙)的性能。实现此目的,与远端故障地面运动相比,基于性能的设计方法的推挽分析的可接受性,但在近场和远场记录下进行了一些非线性时间历史分析以及一些非线性静态分析。检查建筑物的验收标准后。结果表明,尽管在极具故障激励下的双重系统的适当性能,但由于不可受理的故事漂移,在接近故障地面运动下的结构性能是不可接受的。伊朗代码(标准2800号标准2800)的缺陷在柱的地震设计和展示高层建筑物表现中的关键载荷设计和超出分析的不足之处在于该研究的其他结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号