Results of a recently developed refined, high-sensitive electrical resistance (ER) measurement method for corrosion monitoring are presented. Steel probes plated with semi-bright zinc coatings without passivation, with blue chromate, blue chromate and silicate-based sealer and with yellow chromate were tested by the ER method in combination with cyclic corrosion test (CCT) in a salt spray chamber. The ER method is shown to provide fast quantitative corrosion measurements in chamber tests. In most cases an instant corrosion rate can be calculated after a few hours exposure in CCT, whereas visual inspections will require exposure for several days to reveal corrosion. To test the reliability of the ER-measurements as compared to well-known methods, additional corrosion experiments on zinc-plated steel immersed in NaCl-solution were performed. Results from electrochemical impedance spectroscopy (EIS), weight-loss measurements and ER-measurements were in quite good agreement, confirming the reliability of the new ER-method.
机译:介绍了最近开发的精致,高敏感电阻(ER)测量方法的腐蚀监测。通过ER方法与盐雾室中的循环腐蚀试验(CCT)组合,通过盐喷雾室中的循环腐蚀试验(CCT)与含有蓝色铬酸盐,蓝色铬酸盐和基于硅酸盐和基于硅酸盐的密封剂和用黄色铬酸盐进行钝化的钢探针。显示ER方法在腔室测试中提供快速定量的腐蚀测量。在大多数情况下,可以在CCT曝光几小时曝光后计算即时腐蚀速率,而目视检查将需要暴露几天以露出腐蚀。为了测试与众所周知的方法相比,ER-测量的可靠性,进行浸没在NaCl溶液中的锌镀钢上的额外腐蚀实验。电化学阻抗光谱(EIS)的结果,减肥测量和ER-测量非常吻合,确认新的ER方法的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号