首页> 外文会议>International Conference on Structural Integrity >Fatigue lifetime improvement in AISI 304 stainless steel due to high-density electropulsing
【24h】

Fatigue lifetime improvement in AISI 304 stainless steel due to high-density electropulsing

机译:由于高密度电捕,AISI 304不锈钢的疲劳寿命改善

获取原文

摘要

The purpose of the study was to investigate the effect of the use of high density pulsed current (using supercapacitor) on the fatigue life of the tested specimens. For this purpose, experimental analyses were carried out for a two group of samples: without current pulsation and after current exposure. The results of the study for AISI 304 steel (0.04% C, 1.2% Mn, 18.16% Cr, 8% Ni, 0.335% Mo, 0.041% Si) for fatigue strength were presented. The experiments were performed on single edge notched tensile specimen (SENT) with U-shaped electro-drilling (W= 15mm, t = 0.5mm, a_0 = 2.5mm). Positive current pulses with different durations and frequencies were used. The tests were carried out on a hydraulic pulsator MTS 810, controlled by a constant force amplitude F_(max) = 1100N.
机译:该研究的目的是研究使用高密度脉冲电流(使用超级电容器)对测试标本的疲劳寿命的影响。 为此目的,对两组样品进行实验分析:没有电流脉动和电流暴露后。 提出了AISI 304钢(0.04%C,1.2%Mn,18.16%Cr,8%Ni,0.335%Mo,0.041%Si)的研究结果。 用U形电钻(W = 15mm,T = 0.5mm,A_0 = 2.5mm)对单边缘切口拉伸试样(送)进行实验。 使用具有不同持续时间和频率的正电流脉冲。 测试在液压脉冲MTS 810上进行,由恒定力幅度F_(MAX)= 1100N控制。