To investigate odor control for collection system application, a 6,800 m~3 h~(-1) (4,000 cfm) Bioway Purspring~TM biotrickling filter (BTF) was installed at the Hyperion Treatment Plant as first-stage treatment for ventilated sewer air. For second-stage treatment, three types of biofilter media, Biorem, Envirogen, and compost, were evaluated along with two types of activated carbon media, virgin and Midas~TM. The BTF provided 98 percent removal with inlet H_2S as high as 100 ppm. The bulk of the H_2S removal occurred in the lower media with an average H_2S loading rate 24 g m~(-3)h~(-1) and maximum of 76 g m~(-3) h~(-1). When air flow was increased 50 percent, H_2S removal decreased to 94 percent. The BTF performed well with reduced irrigation and with recycled drainage water, but the amount of acid was constant, so neutralization chemical requirements remain unchanged. The BTF provided minimal reduction of the toxic VOCs detected except for toluene. For the Hyperion influent source, the BTF outlet odor averaged about 3,500 D/T, so in addition to being mandated for air quality, second-stage treatment is also needed for odor control. Over the nine-month testing period, there was only one partial loss of treatment, lasting just two days, which was attributed to toxic compounds in the incoming air stream. Biofilters were initially preferred for second-stage treatment, but the testing showed that none of the units yielded acceptable outlet odor. The biofilters reduced BTF odor by about 90 percent, but the final outlet odor of 300 to 500 D/T was not acceptable. The biofilters provided no significant reduction of the toxic VOCs measured with the exception of toluene, which was reduced by 70 percent in the Envirogen and compost media units. The virgin carbon maintained excellent odor control over a nine-month period with a final outlet of 133 D/T and a third-stage outlet of 69 D/T. The virgin carbon media provided good VOC removal except for chloroform and methylene chloride. The second-stage Midas~TM carbon provided excellent odor reduction to 107 D/T and good VOC removal except for chloroform. As a result of the Hyperion testing, the final collection system design was modified from a Bioway BTF followed by a biofilter to a Bioway BTF followed by two stages of virgin carbon.
机译:为了调查收集系统应用的气味控制,在Hyperion治疗厂安装了6,800米〜3 H〜(-1)(4,000cfm)Bioway〜TM BiotRickling过滤器(BTF)作为通风下水道空气的第一阶段处理。对于第二阶段治疗,评估了三种类型的生物过滤介质,Biorem,envirogen和堆肥以及两种类型的活性炭介质,处女和Midas〜TM。 BTF提供98%的入口H_2s,高达100ppm。将大部分H_2S移除在下介质中发生,平均H_2S负载率24g m〜(-3)H〜(-1),最大值为76g m〜(-3)H〜(-1)。当气流增加50%时,H_2S去除降至94%。 BTF的灌溉和再循环排水水良好,但酸的量是恒定的,因此中和化学要求保持不变。 BTF除甲苯外检测到的毒性VOC的最小减少规定。对于Hyperion进水源,BTF出口气味平均约为3,500d / t,因此除了要求空气质量外,还需要对气味控制的第二阶段治疗。在九个月的测试期间,只有一个部分丧失治疗,持续两天,归因于进入空气流中的有毒化合物。最初优选生物过滤器用于第二阶段治疗,但测试表明,没有单位没有得到可接受的出口气味。生物过滤器将BTF气味减少约90%,但是300至500d / t的最终出口气味是不可接受的。生物过滤器没有明显减少甲苯除甲苯外测量的有毒VOC,其在血液引发和堆肥介质单元中减少了70%。维京碳在九个月内保持优异的气味控制,其中最终出口为133d / t和69d / t的第三阶段出口。维珍碳介质除氯仿和二氯甲烷外提供了良好的VOC去除。第二阶段MIDAS〜TM碳提供了优异的气味降低至107d / T和除氯仿外的良好VOC去除。由于Hyperion测试,最终的收集系统设计从BIOWay BTF修改后,然后将生物过滤到BiOWay BTF,然后是维京碳的两个阶段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号