During the period August 2001 to February 2003 global solar UV measurements were performed with a high resolution spectroradiometer at Melbourne Australia (37.7°S, 144.9°E). From these measurements total column ozone amounts were derived and compared with those of a nearby Dobson spectrophotometer. The effects of cloud cover, solar zenith angle and the choice of various parameters used for the total ozone retrieval were examined. The comparison showed that mean difference between the two instruments was either -0.3% or +1.8% depending on the choice of parameters used in the total ozone retrieval. The standard deviation of the differences was 2.7% in both cases. It was observed that the presence of smoke haze increased the difference between the instruments and some preliminary work on reducing this effect is presented.
机译:在2001年8月至2003年2月期间,全球太阳能UV测量在墨尔本澳大利亚的高分辨率光谱仪进行(37.7°S,144.9°E)进行。从这些测量中,衍生出臭氧量的总柱子量并与附近的Dobson分光光度计进行比较。检查了云覆盖,太阳能天性角度和用于总臭氧检索的各种参数的影响。比较表明,根据总臭氧检索中使用的参数的选择,两种仪器之间的平均差异为-0.3%或+ 1.8%。两种情况下差异的标准差为2.7%。观察到烟雾雾度的存在增加了仪器与一些初步工作的差异,提出了降低这种效果。