Observation of Residual Surface Charge Distribution inside an Artificial Air-filled Void due to Partial Discharge Activities at Room and Liquid Nitrogen Temperatures

机译:由于室内排出活性在室外排出活性期间观察人工空气填充空隙内的残余表面电荷分布

获取原文

摘要

Partial discharge (PD) characteristics within an artificial air-filled void contained in a solid insulator were experimentally investigated under 60 Hz ac voltages at liquid nitrogen temperature (77 K) and room temperature of 298 K. The results show that the first PD inception voltage at 77 K is about twice higher than that at 298 K while successive values at both temperatures are almost the same. The results also show that PD charge magnitude noticeably decreases and PD pulse number remarkably increases with the decrease in the temperature from 298 K to 77 K. The latter results are further discussed based on the observed remarkable decrease in the charged area by a single PD on an inner void surface with the decrease in the temperature.
机译:在固体绝缘体中包含的人造充气空隙内的局部放电(Pd)特性在液氮温度(77k)的60 Hz AC电压下进行实验研究,并在298k的室温下进行了实验研究。结果表明了第一PD初始电压在77 k下大约比298 k的两倍高,而两个温度的连续值几乎是相同的。结果还表明,PD电荷幅度明显降低,并且Pd脉冲数随着298k至77k的温度的降低而显着增加。后一种结果是基于单个PD的所观察到的显着降低进一步讨论的内部空隙表面随温度降低。