首页> 外文会议>International Conference on Harmonics and Quality of Power >Influence of the current control loops of DC arc furnaces on voltage fluctuations and harmonics in the HV power supply system
【24h】

Influence of the current control loops of DC arc furnaces on voltage fluctuations and harmonics in the HV power supply system

机译:直流电炉电流控制回路对高压电源系统电压波动和谐波的影响

获取原文

摘要

It is necessary, to an increasing extent, to take controllers and control loops into consideration in mathematical modelling and simulations for power quality studies. DC arc furnaces belong to those electric loads which network behaviour is essentially influenced by control processes. Rated at more than 100 MVA, these furnaces cause voltage fluctuations and harmonics in the HV power system. Based on experiences of onsite measurements at several plants, a mathematical furnace model was completed by implementing phase lock-loop and DC current control loops. The paper shows what influence is exerted to harmonics and flicker severity by the DC furnace current control. Case study calculations are compared to measurement results. It is shown that it is not sufficient to simplify or neglect the control loops in such cases.
机译:在越来越多的情况下,需要考虑到控制器和控制循环,以考虑到电能质量研究的数学建模和模拟。直流电弧炉属于那些网络行为基本上受控制过程影响的那些电荷。额定在100多MVA,这些炉子导致HV电力系统中的电压波动和谐波。基于多个植物的现场测量的经验,通过实现阶段锁环和直流电流控制回路完成了数学炉模型。本文显示了DC炉电流控制互动和闪烁严重程度的影响。将案例研究计算与测量结果进行比较。结果表明,在这种情况下,不足以简化或忽略控制回路。