首页> 外文会议>Student Conference on Electrical Machines and Systems >A Temperature Control Strategy of Fixed Frequency Air Conditioning Loads for Short-Time Peak Clipping
【24h】

A Temperature Control Strategy of Fixed Frequency Air Conditioning Loads for Short-Time Peak Clipping

机译:用于短时峰值剪裁的固定频率空调负荷的温度控制策略

获取原文

摘要

Fixed-frequency Air Conditioning Load(FACL) is the most widely used demand response resource on the user side, and has the characteristics of simple scheduling. In this paper, the operating characteristics of FACL are studied starting from a single device, and the aggregation model of FACL is established. The ratio between the difference value of indoor temperature relative to the dead zone boundary and the dead zone operating temperature of a single FACL is defined as Normalized Temperature Adjustable Capacity (NTAC). Based on NTAC, a temperature control strategy of FACL participating in demand response is proposed in this paper. Simulation results show that this strategy can achieve power extraction without generating rebound load, and has a good engineering application prospect.
机译:固定频率空调负载(FACL)是用户侧最广泛使用的需求响应资源,具有简单调度的特点。在本文中,从单个设备开始研究FACL的操作特性,建立FACL的聚合模型。室内温度相对于死区边界的差值与单个FACL的死区工作温度之间的比率定义为归一化温度可调容量(NTAC)。基于NTAC,本文提出了参与需求响应的FACL的温度控制策略。仿真结果表明,该策略可以实现电力提取而不会产生回弹,并具有良好的工程应用前景。