摘要

Saturated Core Fault Current Limiter offers excellent performance in comparison with conventional measures to limit fault currents. With its appealing practical advantages, the saturated core fault current limiter (SCFCL) has recently demonstrated its application over transmission and distribution power networks. The single-phase, single-core, closed DC - open AC configuration of SCFCL has been experimentally explored in this paper. Based on the measured limiting reactance of SCFCL, a statistical analysis has been carried out under transient conditions. The Monte Carlo simulation (MCS) has been used for this purpose. Moreover, based on the observed population obtained during the steady-state and transient condition, a probability density function and cumulative density function have been plotted for SCFCL reactance.
机译:与常规措施相比,饱和芯滤芯电流限制器提供出色的性能,以限制故障电流。凭借其吸引人的实际优势,饱和核心故障电流限制器(SCFCL)最近展示其在传输和分销电网上的应用。本文实验探讨了SCFCL的单相,单芯,封闭式直流配置。基于SCFC1的测量限制电抗,在瞬态条件下进行了统计分析。 Monte Carlo仿真(MCS)已用于此目的。此外,基于在稳态和瞬态条件下获得的观察群体,绘制了概率密度函数和累积密度函数用于SCFCL电抗。