The analysis of the variation on the machine's back EMF, is done and compared between different levels of partial demagnetization. The interior permanent magnet machine (IPM), has 4 poles designed to be asymmetric with the consequent pole approach. The results from the Finite Element Analysis (FEA) in 2D and 3D are compared to laboratory measurements with same conditions. Good agreement was found for the 3D FEA result's back EMF, making this approach suitable for fault detection and diagnosis studies.
机译:完成了对机器背面电动势变化的分析,并比较了不同水平的部分退磁之间的差异。内置式永磁电机(IPM)具有4个磁极,设计成与随后的磁极方法不对称。将2D和3D有限元分析(FEA)的结果与相同条件下的实验室测量结果进行比较。对于3D FEA结果的反电动势,已经找到了很好的协议,从而使该方法适用于故障检测和诊断研究。