TesTex, Inc. has worked with numerous utilities that experienced Boiler Tube Failures in areas such as water walls, superheaters, reheaters, etc. In this presentation we will discuss specific areas of a given boiler describing what problems (failures) the units were experiencing and what solutions were implemented. We will also discuss various failure mechanisms for boiler tubing, the causes, and various Non-Destructive Testing (NDT) methods used to locate and identify these flaws. Some specific case studies of boiler tube failures are listed below. Xcel Energy-Valmont Station, Boulder, CO Boiler: This 166mw Coal Fired Boiler was experiencing water wall tube failures due to corrosion cells and hydrogen damage. This unit has been inspected with Low Frequency Electromagnetic Technique (LFET) four times over the last seven years. This unit has gone from experiencing tube failures every two weeks to only having 1-2 failures per year. Western, PA Power Plant: This 835 MW Coal Fired Boiler was experiencing reheater tube failures due to oxidation pitting in their horizontal sections. Sections of this reheater were inspected with the Low Frequency Electromagnetic Technique using Low Profile scanners to access the bottom half of the tubes in the horizontal sections. Several flaws were found and repairs were made. Similar inspections were also performed in the plant's other two boilers where no defects were found. These inspections helped the plant locate and make repairs to flawed regions in the boilers. Their run-time between boilers tube failures has risen significantly.
机译:Testex,Inc。已经使用了许多公用事业,在本演示文稿中,在水上墙,超级饮料,再欣赏者等等地区经历了锅炉管故障,我们将讨论一个描述单位在经历的问题(故障)的特定锅炉的特定区域实施了哪些解决方案。我们还将讨论用于定位和识别这些缺陷的各种用于锅炉管道的故障机制,原因和各种无损检测(NDT)方法。下面列出了锅炉管故障的一些具体情况研究。 Xcel Energy-Valmont Station,Boulder,CO锅炉:这款166MW燃煤锅炉由于腐蚀细胞和氢气损坏而经历水壁管故障。该装置已通过低频电磁技术(LFET)在过去七年中进行了四次。该装置从体验到每两周一次的管失败,只有每年有1-2个故障。西部,PA发电厂:这座835兆瓦燃煤锅炉由于其水平部分中的氧化点蚀地区经历了再热器管故障。使用低型材扫描仪使用低频电磁技术检查该再热器的部分,以进入水平部分中管的底部。发现了几个缺陷并进行了维修。在植物的其他两个锅炉中也进行了类似的检查,其中没有发现任何缺陷。这些检查有助于工厂定位并修理锅炉的缺陷区域。锅炉管失败之间的运行时间显着上升。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号