Passive Filter Design to Mitigate Dead-Time Effects in Three-Level T-Type NPC Transformerless PV Inverters Modulated with Zero CMV PWM

机译:无源滤波器设计可缓解零级CMV PWM调制的三电平T型NPC无变压器光伏逆变器的死区影响

获取原文

摘要

Common-mode voltage (CMV) can cause common-mode (CM) current in transformerless PV inverters. In practice, large CM choke is usually required to suppress the CM current. Alternatively, zero common-mode voltage (ZCMV) modulation can be applied to eliminate the CMV. But in practical applications, CMV spikes are inevitable due to the dead-time effect. Such dead-time effect can be mitigated by special PWM sequence design, however, at the expense of increasing switching losses. In this paper, our study addresses this issue by using the DC neutral-point connected LCL (NC-LCL) filter. As the differential-mode (DM) output quality is undermined with ZCMV PWM, the LCL filter parameters must be carefully designed, where both CM and DM filters need to be considered. In addition, filter design for conventional phase disposition (PD) modulation is also included as a comparison. Both simulation results and experimental results are provided for verification.
机译:共模电压(CMV)会在无变压器的PV逆变器中引起共模(CM)电流。实际上,通常需要大的CM扼流圈来抑制CM电流。或者,可以应用零共模电压(ZCMV)调制来消除CMV。但是在实际应用中,由于死区时间效应,CMV尖峰是不可避免的。可以通过特殊的PWM序列设计来减轻这种死区时间影响,但是要以增加开关损耗为代价。在本文中,我们的研究通过使用直流中性点连接的LCL(NC-LCL)滤波器解决了这个问题。由于ZCMV PWM损害了差模(DM)的输出质量,因此必须仔细设计LCL滤波器参数,在此必须同时考虑CM和DM滤波器。另外,作为比较,还包括用于常规相位配置(PD)调制的滤波器设计。仿真结果和实验结果均提供了验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号