This paper suggest an electrical impedance imaging method to detect the corrosion condition of grounding system in online substation directly and reliable. In this paper the principle of this method has been elaborated and we also applied this method in a 500kV substation to check the accuracy. The results shows this method is reliable.
机译:本文提出了一种电阻抗成像方法,可以直接,可靠地检测在线变电站接地系统的腐蚀情况。本文阐述了该方法的原理,并在500kV变电站中应用了该方法以检查其准确性。结果表明该方法是可靠的。