首页> 外文会议>IEEE Electrical Insulation Conference >Dielectric losses diagnosis of serviced aged oil impregnated paper insulation of HV power cables
【24h】

Dielectric losses diagnosis of serviced aged oil impregnated paper insulation of HV power cables

机译:介电损耗诊断服务老化油浸渍纸质隔离的HV电力电缆

获取原文

摘要

This contribution is focused on the application of laboratory dielectric losses measurements to the insulation of service aged oil-impregnated HV power cables. The goal is to investigate the dependence between the electrical and temperature stresses to impregnated paper insulation at different aging stages. By means of laboratory tests with differential transformer testing circuit on aged paper samples the following has been investigated: The influence of voltage stress on tanδ measured on samples taken from different parts of cable insulation: close to conductor, middle part and outer part. The behaviour of dielectric losses as a function of test voltage and temperature for paper samples in different age condition.
机译:该贡献专注于在实验室介电损耗测量中的应用,以对换油的HV电力电缆的保温。目标是研究电气和温度应力与不同老化阶段的浸渍纸质绝缘之间的依赖性。通过对老化纸张样品进行差压变压器测试电路的实验室测试,已经研究了以下内容:电压应力对来自不同部分电缆绝缘材料的样品测量的Tanδ:靠近导体,中间部分和外部。介电损耗的行为作为在不同年龄条件下纸张样品的测试电压和温度的函数。