首页> 外文会议>LWR fuel with enhanced safety and performance meeting >Emergency Response and Solutions for Damaged Fuel Assembly Handling Events Lessons learned from a 2013 fuel positioning issue
【24h】

Emergency Response and Solutions for Damaged Fuel Assembly Handling Events Lessons learned from a 2013 fuel positioning issue

机译:燃油组件处理事件的应急响应和解决方案从2013年燃油定位问题中学到的教训

获取原文

摘要

In 2013, during the refueling of a French 1300 MWe reactor, a fuel assembly was damaged by a fuel assembly positioning tool in the reactor vessel. The upper part of a corner rod of the fuel assembly was twisted and the top end grid was torn off. Because of the protruding fuel rod, the assembly could not be easily transferred for repair to the fuel storage pool via the transfer tube. This unexpected and rarely encountered situation was assessed jointly by EDF and AREVA NP. AREVA NP relied on the expertise of its teams located in France, USA and Germany to assess the different options which could be envisaged. The chosen option was to directly perform the field service inside the reactor building in cells generally used for intermediate storage during refueling This operation, performed by EDF and AREVA, involved removing the twisted rod and positioning it in a special-purpose canister by means of a gripper-type tool for removal and a gripper for holding the rod in place. The special-purpose canister was designed, ordered and supplied by a sub-supplier within one week. As part of the operation, a field service document file was promptly prepared and submitted to the safety regulator; the gripper, which had been designed for in-pool operation, was also requalified. This was a first-of-a-kind in France. The operation, which was performed on the outage critical path, was completed in one day after a week of preparation, thanks to close cooperation between the AREVA NP teams in charge of the operation and the EDF teams. It was also made possible thanks to the field services crisis organization in the AREVA on-site services department which includes a hotline, a worldwide expertise network in the three AREVA regions and an active list of qualified sub-suppliers which can be mobilized at any moment. For EDF, the experience feedback from this operation was the basis for defining an organizational setup for fuel operations in case of a random event affecting the fuel. EDF also reviewed the fuel assembly positioning tools to reduce the risk of a recurring event of this type.
机译:2013年,在法国1300 MWe反应堆的加油过程中,反应堆容器中的燃料组件定位工具损坏了燃料组件。燃料组件的角杆的上部被扭曲,顶端格栅被撕下。由于突出的燃料棒,组件不易通过传输管转移到维修用的燃料储存池中。 EDF和AREVA NP共同评估了这种出乎意料且很少遇到的情况。 AREVA NP依靠其位于法国,美国和德国的团队的专业知识来评估可以设想的各种选择。选择的选择是在加油期间通常用于中间存储的单元中直接在反应堆建筑物内进行现场服务。此操作由EDF和AREVA进行,涉及拆除扭杆并将其放置在专用罐中的方式。夹持器型工具,用于拆卸,以及用于将杆固定到位的夹持器。专用罐是由次级供应商在一周内设计,订购和提供的。作为操作的一部分,迅速准备了现场服务文档文件,并提交给安全管理人员。设计用于池内操作的抓爪也经过了重新鉴定。这是法国的首创。这项工作是在停电关键路径上进行的,经过一周的准备工作,在一天后完成了此工作,这要归功于负责该工作的AREVA NP小组与EDF小组之间的密切合作。这也要归功于AREVA现场服务部门的现场服务危机组织,该组织包括热线电话,三个AREVA地区的全球专业知识网络以及可随时动员的合格合格子供应商的活跃清单。 。对于EDF,在随机事件影响燃料的情况下,此操作的经验反馈是为燃料操作定义组织设置的基础。法国电力公司还审查了燃料组件定位工具,以减少发生此类重复事件的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信