3.7 A 7Gb/s rapid on/off embedded-clock serial-link transceiver with 20ns power-on time, 740μW off-state power for energy-proportional links in 65nm CMOS

机译:3.7 A 7Gb / s快速开/关嵌入式时钟串行链路收发器,具有20ns的上电时间,740μW的断态功率,用于65nm CMOS中的能量比例链路

获取原文

摘要

Energy-proportional operation of serial links is imperative for realizing energy-efficient data centers and low-power mobile interfaces such as MIPI. Burst-mode communication, where the link is powered-off when idle and powered-on when needed, achieves energy proportional operation. Ideally, a burst mode link must be turned on/off in zero time, must consume zero power in the off-state and must incur zero energy overhead while making on/off transitions. However, these requirements are difficult to meet in practice and as a consequence, the efficacy of burst mode communication in achieving energy proportional operation is reduced. The main challenges in achieving small power-on time and off-state power include the design of fast-locking PLLs, CDRs and achieving fast settling of bias node voltages. In this paper, we present a complete 7Gb/s energy-proportional embedded-clock transceiver that achieves less than 20ns power-on time while consuming 63.7mW on-state power, 0.74mW off-state power and 1.2nJ of total transition energy penalty per burst.
机译:串行链路的能量比例操作对于实现节能数据中心和MIPI等低功耗移动接口至关重要。突发模式通信可实现能量比例操作,在这种模式下,链路在空闲时关闭电源,并在需要时打开电源。理想情况下,突发模式链路必须在零时间内开启/关闭,必须在关闭状态下消耗零功率,并且在进行开启/关闭转换时必须产生零能耗。但是,这些要求在实践中很难满足,结果,突发模式通信在实现能量比例操作中的功效降低了。实现较小的上电时间和关闭状态电源的主要挑战包括快速锁定PLL,CDR的设计以及实现偏置节点电压的快速稳定。在本文中,我们介绍了一个完整的7Gb / s能量比例嵌入式时钟收发器,该收发器的上电时间不到20ns,同时消耗63.7mW的通态功率,0.74mW的断态功率和1.2nJ的总过渡能量损耗每次爆发。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号