首页> 外文会议>International sorption heat pump conference >Experimental Investigation on Liquid Desiccant Dehumidification/Regeneration in Falling-Film Plates and Model Validation
【24h】

Experimental Investigation on Liquid Desiccant Dehumidification/Regeneration in Falling-Film Plates and Model Validation

机译:落膜板中液体干燥剂除湿/再生的实验研究及模型验证

获取原文

摘要

To investigate the heat and mass transfer performance of liquid desiccant dehumidification/regeneration in falling-film plates, experiments in the dehumidifier and regenerator using LiCl solution as the liquid desiccant were performed. Effects of inlet air and solution parameters on the air outlet parameters were analyzed experimentally. The empirical correlations of the coupled heat and mass transfer coefficients were presented, and then the NTU-Le heat and mass transfer model was validated through the comparisons of calculation results with experimental data to verify the accuracy and the suitability of the model in the falling-film plate dehumidification/regeneration. The comparison of the heat and mass transfer performance between parallel flow and contra flow is related at the end of this article. The results showed that the error between the results of experiment and simulation was within 10%, and thus it proved that the NTU-Le model were suitable for the liquid desiccant dehumidification and regeneration in falling-film plates. In addition, the experimental results provided reliable data for the further analysis of heat and mass transfer performance between air and desiccant.
机译:为了研究降膜板中液体干燥剂除湿/再生的传热和传质性能,在以LiCl溶液为液体干燥剂的除湿器和再生器中进行了实验。实验分析了进气和溶液参数对出气参数的影响。给出了传热和传质耦合系数的经验相关性,然后通过将计算结果与实验数据进行比较,验证了NTU-Le传热和传质模型,从而验证了该模型在下降过程中的准确性和适用性。薄膜板除湿/再生。在本文的最后,对平行流和逆流之间的传热和传质性能进行了比较。结果表明,实验结果与模拟结果之间的误差在10%以内,证明了NTU-Le模型适用于降膜板中液体干燥剂的除湿再生。此外,实验结果为进一步分析空气与干燥剂之间的传热和传质性能提供了可靠的数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号