首页> 外文会议>International Symposium on Electromagnetic Compatibility >The influence of the scattering probe on the measurement results of electromagnetic fields by the monostatic Modulated Scatterer Technique
【24h】

The influence of the scattering probe on the measurement results of electromagnetic fields by the monostatic Modulated Scatterer Technique

机译:单静态调制散射技术对散射探针对电磁场测量结果的影响

获取原文

摘要

In this paper, the influence of the scattering probe on the measurement results of electromagnetic fields, with the use of the Modulated Scatterer Technique (MST) has been evaluated. Three chosen characteristic locations of field distributions have been analyzed. The distance between the scatterer and an object located in its vicinity has been pointed out as a dominating factor causing the measurement error. The error value has been shown as a function of the mentioned distance. Additionally, the influence of the dipole scatterer size on the measurement error has been analyzed.
机译:在本文中,使用调制散射技术(MST)对散射探针对电磁场测量结果的影响进行了评估。分析了三个选定的场分布特征位置。已经指出散射体和位于其附近的物体之间的距离是引起测量误差的主要因素。误差值已显示为上述距离的函数。此外,已经分析了偶极子散射体尺寸对测量误差的影响。