首页> 外文会议>Conference on photons plus ultrasound: imaging and sensing >Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients
【24h】

Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients

机译:中心静脉氧合的光声测量以评估循环休克:心脏手术患者的临床研究

获取原文

摘要

Circulatory shock is a dangerous medical condition, in which blood flow cannot provide the necessary amount of oxygen to organs and tissues. Currently, its diagnosis and therapy decisions are based on hemodynamic parameters (heart rate, blood pressure, blood gases) and mental status of a patient, which all have low specificity. Measurement of mixed or central venous blood oxygenation via catheters is more reliable, but highly invasive and associated with complications. Our previous studies in healthy volunteers demonstrated that optoacoustic systems provide non-invasive measurement of blood oxygenation in specific vessels, including central veins. Here we report our first results of a clinical study in coronary artery bypass graft (CABG) surgery patients. We used a medical-grade OPO-based optoacoustic system developed in our laboratory to measure in real time blood oxygenation in the internal jugular vein (IJV) of these patients. A clinical ultrasound imaging system (GE Vivid e) was used for IJV localization. Catheters were placed in the IJV as part of routine care and blood samples taken via the catheters were processed with a CO-oximeter. The optoacoustic oxygenation data were compared to the CO-oximeter readings. Good correlation between the noninvasive and invasive measurements was obtained. The results of these studies suggest that the optoacoustic system can provide accurate, noninvasive measurements of central venous oxygenation that can be used for patients with circulatory shock.
机译:循环休克是一种危险的医疗状况,在这种情况下,血液流动无法为器官和组织提供必要量的氧气。当前,其诊断和治疗决策基于患者的血液动力学参数(心率,血压,血气)和精神状态,这些参数均具有较低的特异性。通过导管测量混合或中央静脉血氧合更为可靠,但具有高度侵入性并伴有并发症。我们之前在健康志愿者中进行的研究表明,光声系统可以无创地测量特定血管(包括中心静脉)中的血氧含量。在这里,我们报告在冠状动脉搭桥术(CABG)手术患者中进行的临床研究的第一批结果。我们使用了在我们实验室中开发的基于OPO的医学级光声系统,以实时测量这些患者的颈内静脉(IJV)的血液氧合作用。临床超声成像系统(GE Vivid e)用于IJV定位。作为常规护理的一部分,将导管放置在IJV中,并通过CO血氧仪处理通过导管采集的血液样本。将光声氧合数据与CO-血氧仪读数进行比较。非侵入性和侵入性测量之间获得了良好的相关性。这些研究的结果表明,光声系统可以提供准确的,无创的中心静脉氧合测量,可用于循环休克患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号