首页> 外文会议>Power Plant Air Pollutant Control "MEGA" Symposium >Dry Sorbent Injection (DSI) Suitability for MATS Compliance
【24h】

Dry Sorbent Injection (DSI) Suitability for MATS Compliance

机译:干燥吸附剂注射(DSI)适合垫合规性

获取原文

摘要

EPA has projected 44 MW of Dry Sorbent Injection (DSI) emission control systems to be used for controlling acid gas emissions from coal-fired utility boilers in order to meet the emission standards of the new Mercury Air Toxics Standard (MATS). Based on recent pilot and field trials with calcium reagents, DSI design inputs evaluated in this paper include fuel HCl concentrations, system particulate control technology and reagent properties. In addition, the ability of DSI systems to remove trace metals from flue gas and the resulting byproducts effects on disposal issues for both calcium and sodium based reagents will be addressed. While DSI technology offers advantages in addition to capital savings, including faster implementation schedules than traditional acid gas control technologies, the limitations of the technology must be addressed when developing a compliance strategy.
机译:EPA预计44兆瓦的干吸附剂注入(DSI)排放控制系统,用于控制来自燃煤型锅炉的酸性气体排放,以满足新的汞空气毒素标准(垫子)的排放标准。基于近期与钙试剂的试验和现场试验,本文中评价的DSI设计输入包括燃料HCl浓度,系统颗粒控制技术和试剂性能。此外,DSI系统从烟道气中除去痕量金属的能力以及所产生的副产物对钙和钠基因试剂的处理问题的影响将得到解决。虽然DSI技术除了资本储蓄之外提供优势,但包括比传统的酸性气体控制技术更快的实施时间表,但在制定合规策略时必须解决该技术的局限性。