首页> 外文会议>World conference on timber engineering;WCTE 2012 >EVALUATION OF STRENGTH PROPERIES OF SHEAR WALLS WITH DETERIORATED COMPOSING MEMBERS
【24h】

EVALUATION OF STRENGTH PROPERIES OF SHEAR WALLS WITH DETERIORATED COMPOSING MEMBERS

机译:退化组合构件的剪力墙强度特性评估

获取原文

摘要

Almost 40 years have past since the North American wood frame (two-by-four) construction method became one of the common construction methods for the wooden residential buildings in Japan. The durability of the relatively small cross section size of the framing members, the sheathing materials and the steel connectors such as common nails were in discussion. The object of this research is to evaluate the performance of the shear walls at certain stages of the buildings' service life. The sheathing panels and nails were extracted from wooden existing buildings of certain ages and the extracted sheathing panels and nails were tested for their strength properties. And the strength properties of the aged shear walls were evaluated using a simple structural model and the characteristic values of the aged nail joints.
机译:自北美木结构(二乘四)建筑方法成为日本木制住宅建筑的常见建筑方法以来,已经过去了近40年的时间。讨论了框架构件,护套材料和钢连接器(例如普通钉子)的较小横截面尺寸的耐用性。这项研究的目的是评估建筑物使用寿命中某些阶段的剪力墙性能。护套板和钉子是从一定年龄的木制现有建筑物中提取的,提取的护套板和钉子的强度特性经过了测试。并使用简单的结构模型和老化的指甲接头的特征值对老化的剪力墙的强度特性进行了评估。