首页> 外文会议>Power2011;ASME power conference >HEAT EXCHANGERS FOR COOLING BOILER FLUE GAS TO TEMPERATURES BELOW THE WATER VAPOR DEWPOINT
【24h】

HEAT EXCHANGERS FOR COOLING BOILER FLUE GAS TO TEMPERATURES BELOW THE WATER VAPOR DEWPOINT

机译:换热器,可将锅炉烟气冷却至低于水蒸气露点的温度

获取原文

摘要

Coal-fired power plants have traditionally operated with stack temperatures in the 300℉ range to minimize fouling and corrosion problems due to sulfuric acid condensation and to provide a buoyancy force to assist in the transport of flue gas up the stack. However, as an alternative, there would be benefits to cooling the flue gas to temperatures below the water vapor and acid dew points, while capturing the condensed water vapor.This paper describes experimental results from a DOE and industry-funded project to develop condensing heat exchangers for application to coal-fired power plants. A system of condensing heat exchangers was designed, fabricated and tested using slip streams of boiler flue gas and experiments were performed to measure the effects of process parameters on rates of heat transfer and water vapor condensation. In addition, measurements were made to characterize the acid concentrations in the condensed water which collected on the heat exchanger tubes and to quantify the effects of the heat exchangers on flue gas mercury concentrations.
机译:传统上,燃煤电厂的烟囱温度在300℉范围内运行,以最大程度地减少因硫酸冷凝而引起的结垢和腐蚀问题,并提供浮力以协助烟道气向上烟气的运输。但是,作为替代方案,将烟道气冷却至低于水蒸气和酸露点的温度,同时捕获冷凝的水蒸气将是有益的。本文介绍了能源部和工业资助的开发冷凝热的项目的实验结果。适用于燃煤电厂的换热器。使用锅炉烟气的滑流设计,制造和测试了冷凝式换热器系统,并进行了实验以测量工艺参数对传热率和水蒸气冷凝率的影响。另外,进行测量以表征收集在热交换器管上的冷凝水中的酸浓度,并量化热交换器对烟气中汞浓度的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号