In order to improve the measure performance of gas ultrasonic Doppler Flowmeter in lower velocity, the optimized algorithm of autocorrelation filtering is applied to increase signal to noise ratio. Then by applying Fast Fourier Transform (FFT), frequency is derived and the invalidation problem of Fourier Transform when the velocity is under 0.2m/s is avoided. The result shows that, when the velocity is under 0.08m/s, this method is very efficient in rejecting interference noise and improving successful rate of identifying signals, therefore extends the lower measure limit of ultrasonic Doppler Flowmeter.
机译:为了提高气体超声多普勒流量计的测量性能,较低的速度,应用自相关滤波的优化算法来增加信噪比。然后通过应用快速傅里叶变换(FFT),避免速度频率和傅里叶变换的无效问题避免。避免了0.2M / s。结果表明,当速度低于0.08M / s时,该方法在拒绝干扰噪声和提高识别信号的成功率时非常有效,因此扩展了超声波多普勒流量计的较低测量极限。