A simplified model, which is composed of one tower and two spans of conductors, is given for overhead transmission line system. With tower regarded as cantilever beam and conductor as string, analytical calculation method of wind-induced vibration response of the mechanics system are studied based on the random vibration theory. A factor called dynamic load factor is introduced to the tower. Vibration response and dynamic factor of a typical transmission line is calculated with the method. Results getting from the analytical method are almost the same as that from Finite Element Method (FEM). It indicates the simplified mechanics model is reasonable and practicable, as well as the analytical method. Although responses of tower are different on conditions considering and not considering the coupled vibration affection of conductors, while the factors are about the same value. Then, dynamic load of tower of the former condition is small than that of the later.
机译:针对架空输电线路系统,给出了一个简化模型,该模型由一个塔和两个导体跨度组成。以塔为悬臂梁,导体为线柱,基于随机振动理论,研究了力学系统风致振动响应的解析计算方法。塔中引入了一个称为动态负载系数的系数。用该方法计算出典型传输线的振动响应和动力因数。分析方法得到的结果与有限元方法(FEM)得到的结果几乎相同。说明简化的力学模型以及分析方法是合理可行的。尽管在考虑和不考虑导体耦合振动影响的条件下,塔架的响应是不同的,但这些因素的值大致相同。因此,前一种情况的塔的动载荷比后一种情况的塔的动载荷小。