Based on the lack of studies on indoor thermal environment in residential buildings in China, taking two set of student flats in Qujing Normal University as test rooms, a three-day field survey of indoor thermal environment has been carried out in the present paper. The indoor thermal environment of the two flats is comparatively analyzed by using predicted mean vote /predicted percentage of dissatisfied (PMV/PPD) model. The data indicates that PMV indices fluctuate from -1.10 to -0.65 and from -0.97 to -0.47 for the south-facing room B with a south-facing window and the north-facing room A with a north-facing window, and most of them are less than -0.50. The corresponding PPD values range from 30% to 14.5% and from 24% to 10%. It is evident that the indoor thermal comfort of Room B is better than that of Room A. The relationships between the main indoor and outdoor parameters are also discussed by using the linear regression technique. Many correlations with high relativities have been obtained and they provide people an easy way to predict and assess the indoor thermal environment. The results of this work enrich and develop the basic theory of indoor thermal environment in China.
机译:基于对我国住宅建筑室内热环境研究的缺乏,以曲靖师范学院的两套学生公寓为测试室,对室内热环境进行了为期三天的实地调查。通过使用预测的平均投票/预测的不满意百分比(PMV / PPD)模型对两个公寓的室内热环境进行了比较分析。数据表明,对于带有朝南窗户的朝南房间B和带有朝北窗户的朝北房间A,PMV指数从-1.10到-0.65波动,从-0.97到-0.47波动,并且大多数它们小于-0.50。相应的PPD值范围为30%至14.5%和24%至10%。显然,房间B的室内热舒适性比房间A的好。还使用线性回归技术讨论了主要室内和室外参数之间的关系。已经获得了许多与高相对论的相关性,它们为人们提供了一种预测和评估室内热环境的简便方法。这项工作的结果丰富和发展了中国室内热环境的基本理论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号