In order to find a practical calculation method for mechanical smoke exhaust in atrium, combining with a shopping mall with atrium, this paper made design of the quantity of mechanical smoke exhaust in atrium using performance-based fire protection design method, and simulated the effect of smoke control using Fire Dynamics Simulator. Complying with the Code for fire protection design of tall buildings in China GBSO04. 5-95,the quantity of mechanical smoke exhaust for this atrium should be 104000 m3/h,but in practice, it is not enough, and the quantity of smoke exhaust should be 443520 m3/h calculated by performance-based fire protection design method. The Fire Dynamics Simulator code can be used to investigate the smoke movement in an atrium under fire scenario. According to simulation result, the quantity of mechanical smoke exhaust calculated by performance-basod fire protection design method can make sure safety evacuation.
机译:为了找到一种实用的中庭机械排烟量计算方法,结合有中庭购物商场,采用基于性能的防火设计方法对中庭机械排烟量进行了设计,并模拟了中庭机械排烟量的效果。使用Fire Dynamics Simulator进行烟雾控制。符合《中国高层建筑防火设计规范》 GBSO04。 5-95,该中庭的机械排烟量应为104000 m3 / h,但实际上这还不够,并且应采用基于性能的防火设计方法计算得出的排烟量为443520 m3 / h。 。火灾动态模拟器代码可用于调查火灾情况下中庭中的烟气运动。根据仿真结果,采用基于性能的防火设计方法计算出的机械排烟量可以确保安全疏散。