首页> 外文会议>ASES annual conference;National passive solar conference;Renewable energy policy and marketing conference >COMPREHENSIVE MODELING ON THE INTEGRAL COLLECTION STORAGE UNIT DEMONSTRATED IN A ZERO ENERGY HOUSE
【24h】

COMPREHENSIVE MODELING ON THE INTEGRAL COLLECTION STORAGE UNIT DEMONSTRATED IN A ZERO ENERGY HOUSE

机译:零能耗房屋中集成集合存储单元的综合建模

获取原文

摘要

The University of Nevada Las Vegas (UNLV) Center for Energy Research has completed the efficiency analysis and modeling of the Integral Collection Storage unit installed its Zero Energy Home. Average efficiency range was calculated from a series of week long experiments in which water was drawn with a controlled draw profile. Different draw profiles where used test the ICS unit's performance at both high and low extremes as well as in a normal load range. Calculated average efficiencies ranged from 5.65% to 25.2%, reaching its highest efficiency under the highest loads, and its lowest efficiency under the lowest loads. To get a clear picture of the ICS unit's performance a model was made which could calculate instantaneous efficiency under any load. The instantaneous efficiency of the ICS unit peaked at 98% during the period of initial solar incidence and dropped logorithmatically afterwards.
机译:内华达大学拉斯维加斯分校(UNLV)能源研究中心已完成安装了零能耗房屋的整体馆藏存储单元的效率分析和建模。从一系列为期一周的实验中计算出平均效率范围,在这些实验中以受控的抽吸曲线抽吸水。使用的不同拉伸曲线可以测试ICS单元在高低极限以及正常负载范围内的性能。计算出的平均效率在5.65%至25.2%的范围内,在最高负载下达到最高效率,在最低负载下达到最低效率。为了清楚地了解ICS单元的性能,制作了一个模型,该模型可以计算任何负载下的瞬时效率。 ICS单元的瞬时效率在最初的太阳入射期间达到了98%的峰值,此后逐渐下降。

著录项