【24h】

HYDRAULIC VIBRATION ANALYSIS OF BULB TUBULAR PUMP-HOUSE CONSIDERING FOUNDATION RADIATION DAMPING

机译:考虑地基辐射阻尼的圆管泵房的水力振动分析。

获取原文

摘要

On the basis of pressure pulsations recorded at some locations, the pressure pulsation field of the whole flow passage is structured. Dynamic time-history analysis of pump-house of Huaiyin third pumping station caused by pressure pulsations are carried out to calculate dynamic responses of large-scale bulb tubular pump-house. Compared with the conventional method of fixed boundary with no weight foundation, numerical values of dynamic responses reduce by about 50% at the most considering foundation radiation damping, and the influence of the factor is very prominent to dynamic responses of Huaiyin third pumping station. At the same time, control standards of anti-vibration safety are proposed to evaluate vibration of pump-house. The results indicate that Huaiyin third pump-house meets the requirements of the suggested standards.
机译:根据在某些位置记录的压力脉动,可以构造整个流道的压力脉动场。进行了由压力脉动引起的淮阴第三抽水站泵房的动态时程分析,计算出大型灯泡形管状泵房的动态响应。与传统的无重心固定边界法相比,最大程度地考虑了地基辐射阻尼,动态响应的数值减少了约50%,该因素的影响对于淮阴第三抽水站的动态响应非常突出。同时提出了防振安全控制标准,对泵房的振动进行了评估。结果表明,淮阴第三泵房符合建议标准的要求。