首页> 外文会议>Electrical and Computer Engineering, 2004. Canadian Conference on >On line measurement and improvement of working parameters of a diesel engine-synchronous alternator group
【24h】

On line measurement and improvement of working parameters of a diesel engine-synchronous alternator group

机译:柴油机同步发电机组的在线测量和工作参数的改进

获取原文

摘要

The paper discusses an experiment on a locomotive using a microprocessor-based relay, multiple function relay (MFR), SEL-701, for on line measurement, control and optimization of a HEP (head end power) group. The HEP has a diesel engine, 810-908 HP, 1800 rpm, and a double wound three phase self excited synchronous alternator, 625 kVA, 575 V. The HEP group is installed on the locomotive and supplies the electrical hotel power to the train's coaches. The microprocessor based relay, MFR SEL-701 (Schweitzer Engineering Laboratories) measures the diesel engine temperatures on seven different points and the winding temperatures at three internal points, one per phase. The SEL-701 monitors alternator output currents and voltages and controls one (or both) train lines when the diesel engine's hottest temperature equals the maximum admissible temperature. Amongst other benefits, the paper highlights those derived by use of on line measurements of the diesel engine before and after the relocation of a preexistent engine shutdown temperature probe. In addition, the paper discusses the decrease in the number of diesel engine shut downs due to the modified mode of protection and the increase in available electrical power supplied to the train lines together with the comparison of the HEP group efficiency before and after modification.
机译:本文讨论了使用基于微处理器的继电器,多功能继电器(MFR)SEL-701在机车上进行的实验,以在线测量,控制和优化HEP(前端功率)组。 HEP具有810-908 HP,1800 rpm的柴油发动机和625 kVA,575 V的双绕三相自励同步交流发电机。HEP组安装在机车上,并为火车的教练提供旅馆的电力。基于微处理器的继电器MFR SEL-701(Schweitzer工程实验室)测量柴油发动机温度在七个不同点,绕组温度在三个内部点,每相一个。 SEL-701监视交流发电机的输出电流和电压,并在柴油发动机最热的温度等于最高允许温度时控制一条(或两条)火车线路。在其他好处中,本文重点介绍了在重新定位先前存在的发动机停机温度探头之前和之后使用柴油发动机的在线测量得出的那些好处。此外,本文还讨论了由于修改后的保护模式而减少的柴油机停机次数以及提供给列车线路的可用电功率的增加,以及修改前后的HEP组效率的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号