Raynaud's phenomenon (RP) is a disease characterized by a transient ischemic process, in an exaggerated vascular response to cold or emotional stress. Thermography is a resource applied to support diagnosis of changes in the circulatory system. The aim of the study was to use the DistalDorsal Thermography Difference (DDD) in thermographic images to assess thermal behavior in individuals with secondary RP. The research was carried out in the period between 2018 and 2019. The sample means of the Distal-consisted of 44 individuals in a control group (Control) and 44 individuals in a pathological group (RP2). The participants, after acclimatization, were submitted to the cold stress protocol. The protocol consisted of immersing hands in a container of water at a temperature of 15°C for 60 seconds. The acquisition of thermographic images was performed at the pre-test moment and at the 1st, 3rd, 5th, 7th, 10th and 15th minute. At each time, the DDD values (of all fingers - minimum, maximum and sum) between the groups were analyzed. For statistical analysis, the independent t test and Cohen's d test were used. Regarding the results, there was a difference in relation to the rate of temperature recovery between the groups. The first group showed a rate of reheating just after the first minute subsequent to the cold stress test, while the RP2 group was unable to recover the temperature over 15 minutes. DDD, regardless of the selected criterion, proved to be a valid index for verifying the temperature gradient in the study with individuals identified with secondary RP.
机译:雷诺现象(RP)是一种以短暂的缺血过程为特征的疾病,其对寒冷或情绪应激的血管反应过度。热成像技术是一种用于支持诊断循环系统变化的资源。该研究的目的是在热成像图像中使用远距离热成像差异(DDD)来评估具有继发性RP的个体的热行为。该研究在2018年至2019年期间进行。远端样本的样本均值由对照组(Control)的44个人和病理组(RP2)的44个人组成。适应后,参加者接受了冷应激方案。该方案包括将手浸入温度为15°C的水容器中60秒。在预测试时刻以及第1、3、5、7、10和15分钟进行热成像图像的采集。每次都分析各组之间(所有手指的DDD值-最小,最大和总和)。为了进行统计分析,使用了独立的t检验和Cohen d检验。关于结果,两组之间在温度恢复率方面存在差异。第一组在冷应力测试后的第一分钟之后显示出重新加热的速度,而RP2组在15分钟内无法恢复温度。不论选择哪种标准,DDD都是用于验证研究中具有次级RP的个体的温度梯度的有效指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号