The beam current I_b in a CAMECA SX100 electron probe microanalyser (EPMA) is measured with a pico Ampere meter that makes use of an operational amplifier that is optimised for current to voltage conversion. The feedback element of the operational amplifier is a resistor R and the following equation is valid: V_(out) = I_b * R (1) Currently a problem exists with resistor R: "Unless the resistive element is hermetically sealed in a glass or metal container with glass-to-metal seals, moisture can permeate a resistor and change its resistance'' [1]. This means that the factory calibration of the pico Ampere meter cannot be guaranteed for the whole lifetime of the instrument. In practice, a deviation of 5 % and more can be expected after several years of operation, while for accurate quantitative EPMA analysis this deviation should be less than 0.5 %.
机译:CAMECA SX100电子探针微分析仪(EPMA)中的束电流I_b使用皮安表测量,该皮表使用针对电流到电压转换进行了优化的运算放大器。运算放大器的反馈元件是电阻器R,以下等式有效:V_(out)= I_b * R(1)当前,电阻器R存在问题:“除非电阻性元件被密封在玻璃或金属中装有玻璃对金属密封的容器中,水分会渗透到电阻器中并改变其电阻值” [1]。这意味着无法保证在仪器的整个使用寿命内对皮安培计的出厂校准。在运行数年后,可以预期偏差为5%或更大,而对于准确的EPMA定量分析,该偏差应小于0.5%。