首页> 外文会议>IEEE International Conference on Advanced Power System Automation and Protection >Location and analysis of partial discharge in GIS based on on-line monitoring and improved signal waveform feature method
【24h】

Location and analysis of partial discharge in GIS based on on-line monitoring and improved signal waveform feature method

机译:基于在线监测和改进信号波形特征法的GIS局部放电定位与分析

获取原文

摘要

Online monitoring technology is the real-time monitoring and fault pre-diagnosis of effective GIS technology, the time delay method is a major means of fixing the GIS partial discharge, which is based on the waveform feature points of time delay calculation method has been widely applied in the practical engineering, this paper to improve the signal waveform characteristic point, puts forward the feature points is replaced by a rising edge delay calculation method, through together based on uhf partial discharge phenomena found in the on-line monitoring system, the signal waveform feature points and rising along the method has carried on the comparative study. The research shows that compared with the signal waveform characteristic point method, the rising edge method not only improves the positioning accuracy, but also inherits the advantages of simple operation and low cost of signal waveform characteristic point method, which has certain engineering application value.
机译:在线监测技术是有效的GIS技术的实时监测和故障预诊断,时延方法是固定GIS局部放电的主要手段,它基于波形特征点的时延计算方法已得到广泛应用在实际工程中的应用,本文对信号波形的特征点进行了改进,提出了用上升沿延迟计算方法代替特征点,结合基于在线监测系统中发现的超高频局部放电现象,对信号进行了改进。波形特征点与上升沿方法进行了对比研究。研究表明,与信号波形特征点法相比,上升沿法不仅提高了定位精度,而且继承了信号波形特征点法操作简单,成本低廉的优点,具有一定的工程应用价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号